Study: Noncystic Fibrosis Bronchiectasis: Regional Abnormalities and Response to Airway Clearance Therapy Using Pulmonary Functional Magnetic Resonance Imaging

Study

Noncystic Fibrosis Bronchiectasis: Regional Abnormalities and Response to Airway Clearance Therapy Using Pulmonary Functional Magnetic Resonance Imaging

Finding

“There was CT and MRI evidence of structure-function abnormalities in patients with bronchiectasis; in approximately half, there was evidence of ventilation improvements after airway clearance therapy.”

Abstract

Rationale and objectives: Evidence-based treatment and management for patients with bronchiectasis remain challenging. There is a need for regional disease measurements as focal distribution of disease is common. Our objective was to evaluate the ability of magnetic resonance imaging (MRI) to detect regional ventilation impairment and response to airway clearance therapy (ACT) in patients with noncystic fibrosis (CF) bronchiectasis, providing a new way to objectively and regionally evaluate response to therapy.


Materials and methods: 
Fifteen participants with non-CF bronchiectasis and 15 age-matched healthy volunteers provided written informed consent to an ethics board-approved Health Insurance Portability and Accountability Act-compliant protocol and underwent spirometry, plethysmography, computed tomography (CT), and hyperpolarized 3He MRI. Bronchiectasis patients also completed a Six-Minute Walk Test, the St. George’s Respiratory Questionnaire, and Patient Evaluation Questionnaire (PEQ), and returned for a follow-up visit after 3 weeks of daily oscillatory positive expiratory pressure use. CT evidence of bronchiectasis was qualitatively reported by lobe, and MRI ventilation defect percent (VDP) was measured for the entire lung and individual lobes.


Results: 
CT evidence of bronchiectasis and abnormal VDP (14 ± 7%) was observed for all bronchiectasis patients and no healthy volunteers. There was CT evidence of bronchiectasis in all lobes for 3 patients and in 3 ± 1 lobes (range = 1-4) for 12 patients. VDP in lobes with CT evidence of bronchiectasis (19 ± 12%) was significantly higher than in lobes without CT evidence of bronchiectasis (8 ± 5%, P = .001). For patients, VDP in lung lobes with (P < .0001) and without CT evidence of bronchiectasis (P = .006) was higher than in healthy volunteers (3 ± 1%). For all patients, mean PEQ-ease-bringing-up-sputum (P = .048) and PEQ-patient-global-assessment (P = .01) were significantly improved post-oscillatory positive expiratory pressure. An improvement in regional VDP greater than the minimum clinical important difference was observed for 8 of the 14 patients evaluated.


Conclusions: 
There was CT and MRI evidence of structure-function abnormalities in patients with bronchiectasis; in approximately half, there was evidence of ventilation improvements after airway clearance therapy.


https://pubmed.ncbi.nlm.nih.gov/27717759/

Cited

Svenningsen S, Guo F, McCormack DG, Parraga G. Noncystic Fibrosis Bronchiectasis: Regional Abnormalities and Response to Airway Clearance Therapy Using Pulmonary Functional Magnetic Resonance Imaging. Acad Radiol. 2017;24(1):4-12. doi:10.1016/j.acra.2016.08.021

Interested in Turboforte?

Turboforte Lung Physio is a handheld drug-free lung expansion & mucus relief device that helps clear congestion from airways and lungs making breathe easier.

Related News

What are the best Airway Clearance methods?

Each and every day, our body produces mucus to ease the movement of foreign objects inside our airways. But what happens when our body produces too much sticky and viscous mucus?

In diseases that stimulate too much mucus production, like cystic fibrosis, bronchiectasis and COPD, airway clearance techniques and devices are important to clear your airways.

Read More »

What is a flutter valve?

A flutter valve is a one-way valve used in respiratory medicine to prevent air from travelling back along a chest tube.

A flutter valve device, on the other hand, is a device used by individuals to mobilize mucus and expand airways.

When exhaling into the device, a steel ball resting on a cone begins to vibrate, causing oscillation through the whole airway, which in turn mobilizes sticky mucus.

Read More »